‘Genix’ technology
Genix is our patented technology utilised in many of our products. The key to Genix...
Find out moreThe DGELF-POD differential I/O carrier with fault insertion and loading supports a range of DSP based I/O modules supporting up to 32 channels of fully configurable, single and differential I/O, with voltage, current, frequency, resistance and complex waveform capabilities.
Up to 16 DSP modules can be fitted to the DGELF pod which may be configured via one of more distributed CAN networks to support an extensive range of applications. Each module may also be programmed with different firmware.
High current, low insertion loss, fully protected and monitored fault insertion is integrated into these PODs, supporting fault injection for inputs and outputs onto two separate fault buses.
The optional load board supports up to 16 channels of single-ended or differential loading capability with HIL I/O control options.
Interested?Leave your details below to receive a copy of the latest Genix leaflet: |
• Built-in fault insertion | • Configurable real-time interface via CAN |
• Software & jumper selectable configurations | • Complex functions using teaming |
• Simulink TSP compatible |
Parameter | Specification |
ECM I/O+ | ±60V |
ECM I/O- | ±60V |
Imax out (continuous) | 5A |
Imax out (transient) | 8A |
Operating temperature | 10..+50°C |
Carrier board internal power dissipation | 4W |
Genix V+ to V- | 36V |